= DPL over Ethernet (DPLoE) =
 +
 +
== Preparation ==
 +
 +
DPL over Ethernet (DPLoE) requires a stable network connection to the DPL-capable network
 +
printer and a static IP on the printer.
 +
 +
HVS32 supports DPLoE from version 7.96.58
 +
 +
DPLoE is an alternative to the previous COM/LPT port but does not offer any driver
 +
driver functionalities such as a printer queue.
 +
For this reason, the printer should only be controlled from one packing station. Tests have shown
 +
that labels can be skipped if there are too many requests from packing stations.
 +
 +
== Setup ==
 +
 +
Setup is carried out via the General Configurator. setup -> configurator -> general ->
 +
label printer. There you will find the additional printer port: TCP/IP
 +
 +
[[File:DPLoE.JPG|571x325px|RTENOTITLE]]
 +
 +
After pressing this button, an input window appears where the TCP and DPL parameters
 +
can be defined:
 +
 +
[[File:DPLoE.1.JPG|571x325px|RTENOTITLE]]
 +
 +
IP und Port bitte aus Ihrer Druckerkonfiguration entnehmen. Unter Timeout kann man die maximale
 +
Wartezeit festlegen, bis das HVS32 einen Fehler ausgibt, sollte der Drucker nicht erreichbar sein.
 +
Validate ist ein DPL-Feature, welches prüft und das HVS32 solange warten lässt, bis das Label am
 +
Drucker fertig ausgedruckt wurde.
 +
Ready Check ist eine Überprüfung vor dem Druck, ob der Drucker auch tatsächlich bereit ist, das Label
 +
sofort auszudrucken (es besteht also keine Warteschlange im Drucker selbst). Das HVS32 wartet
 +
standardmäßig bis zu 5 Sekunden, bevor es einen Fehler ausgibt.
 +
Sowohl Validate als auch Ready Check sind erweiterte DPL-Funktionen, welche nicht unbedingt von
 +
jedem DPL-Drucker unterstützt werden. Zusätzlich wird eine Fehlermeldung ausgegeben, welche als
 +
DPL-Druckerfehler behandelt wird (vorher z.B. falls COM1 nicht bereit war), dies kann das Automatikpolling stoppen. Deswegen ist einer Verwendung dieser Funktionen nur zum Testen der Drucker
 +
geeignet.
 +
Ab sofort können auch alle DPL-Konfigurationen direkt im Konfigurator getestet werden. Dies gilt für
 +
alle Drucker-Arten unter der Gruppe „Datamax (DPL)“:
 +
 +
[[File:DPLoE2.JPG|571x325px|RTENOTITLE]]
 +
 +
 +
= DPL Spooling =
 +
 +
== Anforderungen ==
 +
 +
* Modul WinPrint 1:1
 +
* Genügend Spooler Lizenzen
 +
* Funktionierender Druck über DPLWinPrint oder DPLoE
 +
 +
== Einrichtung ==
 +
 +
Das DPL-Spooling ist ein Teil des zentralen Pollings vom HVS32. Der Ausgabekanal muss also aus
 +
dem Feld „Druckername“ kommen.
 +
Da das HVS32-Spooling fest mit WinPrint 1:1 verbaut ist, benötigt man
 +
zum Aktivieren des DPL-Spoolings das Modul WinPrint 1:1. Als aktiven
 +
Drucker wählt man auch WinPrint 1:1 aus.
 +
In den Ausgabekanal-Einstellungen hat man nun 2 weitere Typen:
 +
DPLoE (Spooler) und DPLWinPrint (Spooler):
 +
 +
[[File:DPLoE3.JPG|571x325px|RTENOTITLE]]
 +
[[File:DPLoE4.JPG|571x325px|RTENOTITLE]]
 +
 +
Beide Typen sind nur für das zentrale Polling gedacht und dürfen in den Stationseinstellungen nicht
 +
als Etikettenausgabe eingestellt werden.
 +
 +
[[File:DPLoE5.JPG|571x325px|RTENOTITLE]]
 +
 +
Die jeweils wichtigsten Parameter für diesen Ausgabekanaltyp werden direkt abgefragt. Als Hilfe dient
 +
z.B. das HVS32 Testetikett aus der DPL-Konfiguration. Gerade das DPLWinPrint lohnt sich für das
 +
HVS32-Spooling, da hier auch wirklich eine Art Spooler hinten dran hängt in Form eines Treibers, der
 +
allerdings die DPL-Kommandos 1:1 durchgibt.

Version vom 3. November 2023, 15:52 Uhr


DPL over Ethernet (DPLoE)

Preparation

DPL over Ethernet (DPLoE) requires a stable network connection to the DPL-capable network printer and a static IP on the printer.

HVS32 supports DPLoE from version 7.96.58

DPLoE is an alternative to the previous COM/LPT port but does not offer any driver driver functionalities such as a printer queue. For this reason, the printer should only be controlled from one packing station. Tests have shown that labels can be skipped if there are too many requests from packing stations.

Setup

Setup is carried out via the General Configurator. setup -> configurator -> general -> label printer. There you will find the additional printer port: TCP/IP

RTENOTITLE

After pressing this button, an input window appears where the TCP and DPL parameters can be defined:

RTENOTITLE

IP und Port bitte aus Ihrer Druckerkonfiguration entnehmen. Unter Timeout kann man die maximale Wartezeit festlegen, bis das HVS32 einen Fehler ausgibt, sollte der Drucker nicht erreichbar sein. Validate ist ein DPL-Feature, welches prüft und das HVS32 solange warten lässt, bis das Label am Drucker fertig ausgedruckt wurde. Ready Check ist eine Überprüfung vor dem Druck, ob der Drucker auch tatsächlich bereit ist, das Label sofort auszudrucken (es besteht also keine Warteschlange im Drucker selbst). Das HVS32 wartet standardmäßig bis zu 5 Sekunden, bevor es einen Fehler ausgibt. Sowohl Validate als auch Ready Check sind erweiterte DPL-Funktionen, welche nicht unbedingt von jedem DPL-Drucker unterstützt werden. Zusätzlich wird eine Fehlermeldung ausgegeben, welche als DPL-Druckerfehler behandelt wird (vorher z.B. falls COM1 nicht bereit war), dies kann das Automatikpolling stoppen. Deswegen ist einer Verwendung dieser Funktionen nur zum Testen der Drucker geeignet. Ab sofort können auch alle DPL-Konfigurationen direkt im Konfigurator getestet werden. Dies gilt für alle Drucker-Arten unter der Gruppe „Datamax (DPL)“:

RTENOTITLE


DPL Spooling

Anforderungen

  • Modul WinPrint 1:1
  • Genügend Spooler Lizenzen
  • Funktionierender Druck über DPLWinPrint oder DPLoE

Einrichtung

Das DPL-Spooling ist ein Teil des zentralen Pollings vom HVS32. Der Ausgabekanal muss also aus dem Feld „Druckername“ kommen. Da das HVS32-Spooling fest mit WinPrint 1:1 verbaut ist, benötigt man zum Aktivieren des DPL-Spoolings das Modul WinPrint 1:1. Als aktiven Drucker wählt man auch WinPrint 1:1 aus. In den Ausgabekanal-Einstellungen hat man nun 2 weitere Typen: DPLoE (Spooler) und DPLWinPrint (Spooler):

RTENOTITLE RTENOTITLE

Beide Typen sind nur für das zentrale Polling gedacht und dürfen in den Stationseinstellungen nicht als Etikettenausgabe eingestellt werden.

RTENOTITLE

Die jeweils wichtigsten Parameter für diesen Ausgabekanaltyp werden direkt abgefragt. Als Hilfe dient z.B. das HVS32 Testetikett aus der DPL-Konfiguration. Gerade das DPLWinPrint lohnt sich für das HVS32-Spooling, da hier auch wirklich eine Art Spooler hinten dran hängt in Form eines Treibers, der allerdings die DPL-Kommandos 1:1 durchgibt.