HVS32 Update - Preperation

during the update it is not possible to work/process with HVS32. All HVS32 stations must be closed.
If you use HVS32Monitorings Services, the services should be shut down before the update.
By using the windows computer managment (on the hvs32 server) -> shared folders -> open files you can check if there are still files opened/being accesed on the hvs32 share. You can close them here if needed. Be aware that this might cause error messages on the attached stations. These can be ignored as long as HVS32 starts normally afterwards.

The update has to be done on the server (if you have a single-station then on the only workstation).

HVS32 Update-Auswahlmöglichkeiten


Before the update do a backup/copy of your hvs32 folder. Backup / copy your database also if its not included in the hvs32 folder.

The copying process can only be done if there is no user connected to the database and no HVS32 is runnning, otherwise you will loose data and the database will be corrupt.

To be sure that no user is connected anymore you can stop the firebird service on the server. (servicenames: FB 2.5 "FirebirdServer", FB 1.5: "Firebird Server - DefaultInstance" and "Firebird Guardian - DefaultInstance").
Attention: If you are runnning nbackup dont stop the firebird services while there is a backup running. Else the database would remain in a Backup state which cannot be restored.

link to the newest hvs32 version

You can get the link from the support, with an active support contract you will receive the link and manual at no extra charge.

how to

Run the HVS32Setup.exe (recommended -> right click -> run as administrator).
Follow the setup and choose the option "update". Be sure that the correct HVs32 installationfolder is marked.
If the path is wrong go back and select "new installation", then you will be able to choose a path manually. During an update it is not necessary to create desktop icons or to install the Firebird server, this is only required on the very first installation ever. This can also be necessary if you are running more than 1 HVS32 installation on the server with different folders.

Attention: the update routing can add a additional folder "HVS32" (C:\Heidler\HVS32\HVS32), this has to be removed

After the update, start the firebirdservice again. If you using the old version of the dhl routing / leitcode service "Kelvin..." restart it.

Now run HVS32.exe as administrator on the server. A few message boxes will appear and inform you of the internal updating process, press ok. After that the database update will start if required. This might take several minutes depending on your database size and server speed. If HVS32 suggests a "Full Database Restructure" e recommend that you contact HVS support as this process is very time consuming and should be avoided if at all possible.

Troubleshoot

If there is a message after the update that there are 2 or more users connected to the database and hvs32 is closing, there is a hvs32 station already runnning or a firebird process is connected to the database. In this case restart the firebird service.

If there is a message regarding a full restructuring ("Vollrestrukturierung"), cancel the process and contact our support. The full restructuring can run a few hours.